XMP, Elektronika, Zasilacze i przetwornice AC-DC DC-DC noty katalogowe EDW, Noty zasilacze, Elsinco, ZASILACZE, DC, XANTREX

Poza tym na świecie jest niewiele istot groźniejszych od kobiety.

Smart choice for power
Multiple Output Programmable
DC Power Supply System
Modular Multiple Output DC Power System
The XMP 2600 is a multiple output programmable DC power system, offering the highest power per
module from any manufacturer. The XMP 2600 can be customized by selecting up to 8 of 22 different
power modules. These modules range from 160 W to 2.4 kW, providing a maximum output of 2.6 kW.
The XMP is designed to efficiently test a variety of loads simultaneously or to replace multiple power
supplies with a single unit. Software within the XMP 2600’s mainframe controller can instantly
reconfigure the system to provide eight channels with different voltage and current outputs.
By adding one or more extension slave units, the XMP can provide up to 16 outputs and 38 kW
under a single GPIB address.
The XMP 2600 was designed to be flexible and customizable for high-level test and OEM applications
in automotive, military, semiconductor manufacturing, burn-in and ATE applications.
Product Features:
19” x 5 1/4” (3 U high) mainframe accommodates up to eight modules
1/8, 2/8 and 3/8 width modules from 160W to 2.4 kW, and 0-8 V to 0-160 V and 1.25 A to 80 A
Power envelope: 2.4 kW, 2.6 kW intermittent
Power envelope monitoring and control
Individual module processor control
GPIB and RS-232 interfaces for simultaneous control and monitoring
99-step auto sequencing
Workpoint window provides continuous monitoring, warning and shutdown to ensure voltage
and current remain within programmed levels
Built-in disconnect and automatic polarity reversal relays
Extensive DUT and load protection
Polarity and isolation delays
External synchronization
Extensive DUT protection features
10 multi-channel store/recall locations
Software-based calibration
Local panel and keyboard
Low ripple and noise
Power factor correction (PFC)
Xantrex Technology Inc.
Headquarters
8999 Nelson Way
Burnaby, British Columbia
Canada V5A 4B5
800 670 0707 Toll Free
604 420 1591 Fax
5916 195th Street NE
Arlington, Washington
USA 98223
800 446 6180 Toll Free
360 925 5144 Fax
www.xantrex.com
© 2006 Xantrex Technology Inc. All rights reserved. Xantrex is a registered trademark of Xantrex International. Printed in Canada.
Smart choice for power
Multiple Output Programmable DC Power Supply System
General Speciications
AC input
170 V - 265 V Iin < 20 A nominal
Nomimal 120 V, Po < 1 kW Iin < 15 A nominal
Mains frequency 45 to 66 Hz
Power cord length 2 m
Power factor correction (PFC) Power factor correction to meet EN61000-3-2 Current Harmonics and EN61000-3-3 Voltage Fluctuations (IEC555)
Inrush current
Up to 100% of speciied nominal current
Input mains protection
Circuit breaker switch on the front panel
Environmental conditions
Storage temperature -20°C to 70°C
Operating temperature 0°C to 55°C (LCD to 50°C)
Derate output current/power 1% per °C from 30°C to 55°C
Regulatory approvals
European standards
Electromagnetic Emissions and Immunity - meets Council Directive 89/336/EEC
Electromagnetic emissions
EN61326: 1997 + A1: 1998
EN61000-3-2: 2000
EN61000-3-3: 1995
Electromagnetic Immunity
EC61326: 1997 + A1: 1998
Safety agency compliance
European standards
Safety
Meets EN61010-1
American standards
Electromagnetic emissions Meets FCC Class B
Safety
Meets UL61010-1
Temperature coeficient
Voltage programming 0.01% per °C
Current programming 0.02% per °C
Voltage readback 0.01% per °C
Current readback 0.02% per °C
Long term drift Output change after 30 min. warm-up, over an interval of 8 hours under constant load, line and temperature conditions is 0.03%.
Remote sensing Up to 4 V can be dropped over the two load lines together (i.e. 1.5 V + 2.5 V). At 2.5 V a warning event will be generated, alerting over sense
voltage drop condition, and at 4V the module will be shut down. The load lines drop subtracts from the voltage available for the load.
Output programming response time Rise and fall time with full resistive load (10 to 90% and 90 to 10%) is 30-640 mSec.
Isolation
Output terminals can be loated up to +/- 240 Vdc from chassis ground
*Data subject to change without notice.
Module Speciications
*1, 2
Module order code
A1 B1 C1 D1 E1 A2 B2 C2 D2 E2 A4
Module width
1/8 1/8 1/8 1/8 1/8 1/8 1/8 1/8 1/8 1/8 2/8
Output ratings
Power
160 W 180 W 180 W 200 W 200 W 320 W 360 W 360 W 400 W 400 W 640 W
Voltage
8 V 18 V 36 V 80 V 160 V 8 V 18 V 36 V 80 V 160 V 8 V
Current
20 A 10 A 5 A 2.5 A 1.25 A 0 A 20 A 10 A 5 A 2.5 A 80 A
Module order code
B3 C3 D3 E3 B4 C4 D4 E4 C5 D5 E5
Module width
1/8 1/8 1/8 1/8 2/8 2/8 2/8 2/8 3/8 3/8 3/8
Output ratings
Power 720 W 720 W 720 W 720 W 1,440 W 1,440 W 1,600 W 1,600 W *(3) *(3) *(3)
Voltage 18 V 36 V 80 V 160 V 18 V 36 V 80 V 160 V 36 V 80V 160V
Current 40 A 20 A 9 A 4.5 A 80 A 40 A 20 A 10 A 80 A 40A 20A
*(1) - Speciications subject to change without notice.
*(2) - Speciications refer to a chassis with only the speciied module installed, with nominal resistive load (90% of rated current at the rated voltage) and the power supply sensing locally at the rear terminals, at 25°C.
*(3) - The maximum output power is limited by the mainframe power envelope.
© 2006 Xantrex Technology Inc. All rights reserved. Xantrex is a registered trademark of Xantrex International. Printed in Canada.