YAMATAKE SDC15 instalation&config manual, sterowniki PID rożne

Poza tym na świecie jest niewiele istot groźniejszych od kobiety.

//-->.pos {position:absolute; z-index: 0; left: 0px; top: 0px;}No. CP-SP-1148ESDC15Single Loop ControllerUser's ManualforInstallation & ConfigurationThank you for purchasing the SDC15Single Loop Controller.This manual contains information forensuring correct use of the SDC15. Italso provides necessary information forinstallation, maintenance, and trou-bleshooting.This manual should be read by thosewho design and maintain devices thatuse the SDC15.Be sure to keep this manual nearby forhandy reference.RESTRICTIONS ON USEThis product has been designed, developed and manufactured for general-purposeapplication in machinery and equipment.Accordingly, when used in applications outlined below, special care should be taken toimplement a fail-safe and/or redundant design concept as well as a periodicmaintenance program.• Safety devices for plant worker protection• Start/stop control devices for transportation and material handling machines• Aeronautical machines• Aerospace machines• Control devices for nuclear reactorsNever use this product in applications where human safety may be put at risk.REQUESTEnsure that this User's Manual is handed over to the user before theproduct is used.Copying or duplicating this User's Manual in part or in whole is forbid-den. The information and specifications in this User's Manual are sub-ject to change without notice.Considerable effort has been made to ensure that this User's Manual isfree from inaccuracies and omissions.If you should find any inaccuracies or omissions, please contactYamatake Corporation.In no event is Yamatake Corporation liable to anyone for any indirect,special or consequential damages as a result of using this product.©2003 Yamatake Corporation ALL RIGHTS RESERVEDSAFETY REQUIREMENTSTo reduce risk of electric shock which could cause personal injury, follow all safetynotices in this documentation.This symbol warns the user of a potential shock hazard where hazardous live voltagesmay be accessible.•If the equipment is used in a manner not specified by the manufacturer, the protection••••provided by the equipment must be impaired.Do not replace any component (or part) not explicitly specified as replaceable by yoursupplier.All wiring must be in accordance with local norms and carried out by authorized andexperienced personnel.A switch in the main supply is required near the equipment.Main power supply wiring requires a (T) 200mA, 250V fuse(s) (IEC 127).EQUIPMENT RATINGSSupply voltages:100 to 240V (operating power supply voltage 85 to 264Vac)Frequency:50/60HzPower consumption:12VA maximumEQUIPMENT CONDITIONSDo not operate the instrument in the presence of flammable liquids or vapors.Operation of any electrical instrument in such an environment constitutes a safety hazard.Temperature:0 to 50˚CHumidity:10 to 90%RH (no condensation)Vibration:2m/s2(10 to 60Hz)Over-voltage category:Category II (IEC60364-4-443, EN664-1)Pollution degree:Pollution degree 2EQUIPMENT INSTALLATIONThe controller must be mounted into a panel to limit operator access to the rear terminal.Specifications of common mode voltage: The common mode voltages of all I/O except for mainsupply and relay outputs are less than 33Vrms, 46.7V peak and 70Vdc.APPLICABLE STANDARDSEN61010-1, EN61326-1iSAFETY PRECAUTIONS■About IconsSafety precautions are for ensuring safe and correct use of this product, and forpreventing injury to the operator and other people or damage to property. Youmust observe these safety precautions. The safety precautions described in thismanual are indicated by various icons.As the following describes the icons and their meanings, be sure to read andunderstand the descriptions before reading this manual:WARNINGCAUTION■ExamplesWarnings are indicated when mishandling this product mightresult in death or serious injury to the user.Cautions are indicated when mishandling this product mightresult in minor injury to the user, or only physical damage tothis product.Triangles warn the user of a possible danger that may be caused bywrongful operation or misuse of this product.These icons graphically represent the actual danger. (The example onthe left warns the user of the danger of electric shock.)White circles with a diagonal bar notify the user that specific actions areprohibited to prevent possible danger.These icons graphically represent the actual prohibited action. (Theexample on the left notifies the user that disassembly is prohibited.)Black filled-in circles instruct the user to carry out a specific obligatoryaction to prevent possible danger.These icons graphically represent the actual action to be carried out.(The example on the left instructs the user to remove the plug from theoutlet.)iiWARNINGDo not disassemble the SDC15.Doing so might cause electric shock or faulty operation.Before wiring, or removing/mounting the SDC15, be sure to turn thepower OFF.Failure to do so might cause electric shock.Do not touch electrically charged parts such as the power terminals.Doing so might cause electric shock.CAUTIONUse the SDC15 within the operating ranges recommended in thespecifications (temperature, humidity, voltage, vibration, shock,mounting direction, atmosphere, etc.).Do not block ventilation holes.Doing so might cause fire or faulty operation.Wire the SDC15 properly according to predetermined standards.Also wire the SDC15 using specified power leads according torecognized installation methods.Failure to do so might cause electric shock, fire or faulty operation.Do not allow lead clippings, chips or water to enter the controller case.Doing so might cause fire or faulty operation.Firmly tighten the terminal screws at the torque listed in thespecifications.Insufficient tightening of terminal screws might cause electric shock orfire.Do not use unused terminals on the SDC15 as relay terminals.Doing so might cause electric shock, fire, or faulty operation.We recommend attaching the terminal cover (sold separately) afterwiring the SDC15.Failure to do so might cause electric shock, fire, or faulty operation.Use the relays within the recommended life.Failure to do so might cause fire or faulty operation.Use Yamatake Corporation's "SURGENON" if there is the risk of powersurges caused by lightning.Doing so might cause fire or faulty operation.Do not make incorrect connections. If the cables are connectedincorrectly, this might cause the unit to malfunction.The controller does not function for approximately 6 sec. after thepower has been turned ON. Great care should be taken when the relayoutput from the controller is used as interlock signals.iii
  • zanotowane.pl
  • doc.pisz.pl
  • pdf.pisz.pl
  • kachorra.htw.pl